The Pipe Insulation command part of the PowerPack for Revit ribbon creates insulation on pipes and ducts based on the system type and thickness settings.

Split Pipes command
Click on the Pipe Insulation command and PowerPack will begin to scan your project. PowerPack automatically detects if certain types already exist in the project:

Duplicate types
The command automatically assigns insulation to the systems based on parameters such as the outer or inner diameter, or assigns a specific value.

Pipe Insulation configuration
Click on the settings button
to access the Configurations manager dialog and add presets based on the rules that are currently used.
Implicitly, the dialog only shows a default configuration. You can create new configurations by clicking on the Add new button, which opens a new dialog used for entering a configuration name. Configurations can be exported and saved, for use in other projects. Presets can also be imported using the Import from file button.

Create or import configurations
After you finish creating/importing/exporting the configuration presets, they will be listed in the current configuration drop-down menu, where they can be easily accessed and used. The major advantage of the tool is that all three disciplines in Revit can have separate presets.
In the Apply insulation for chosen systems dialog, check the desired systems for which the insulation will be applied.
Insulation per system type:
System type: the drop-down contains all Revit system types that can be insulated, allowing you to select a system type on which to apply the insulation. This function speeds up the long process of applying insulation to a large number of pipes.

System type
Insulation type: the drop-down lists all pipe insulation materials present in the project.

Insulation type
Insulation thickness: lists a collection of parameters that can be added or deleted. The list of parameters defines a set of functions in which the task can perform. For example, pipes with a diameter between 3.50 cm and 10 cm will be insulated based on a fixed value of 3.50 cm.
The Diameter from parameter shows the default thickness of the insulation
The Diameter to parameter is editable and allows you to input of a maximum diameter to define a specific range of pipe dimensions in which the command should perform.
You can choose from Fixed value, Inner or Outer diameter to define the insulation thickness.
You can also set a value for the insulation thickness.
Check the box if you wish to Apply insulation to fittings. However, this is applicable if and only if all other elements in the system have the same insulation thickness.
Click on the OK button to apply insulation to previously set elements. You can check the added insulation in the Project Browser:

Project Browser