Launch the Verify command to perform a verification considering the real reinforcement in place. Useful to be used after the Constructive Dispositions command is applied, when reinforcement cage is customized after calculation or when the reinforcement cage is manually defined from scratch.
When applying the Calculate, Footing Presizing or Verify commands, the Errors and warnings tab in the console displays warning and error messages regarding the design of the footing.

Errors and warnings tab
The main warnings and errors that may appear in the console are:
No HA available
Unable to create anchorage
Soil stress exceeded at the ULS
Soil stress exceeded at the SLS
Soil bearing resistance failed at SLS. Increase footing dimensions.
Sliding along Ox too large
Sliding along Oy too large
Overturning along Ox too large
Overturning along Oy too large
Footing entirely uplifted at the ULS
The column punches the footing (x = <<val Abscissa>>)
The wall punches the footing
The footing floats
Footing is not supported by bearing soil
Blinding concrete is not cast on bearing soil
Coarse concrete is not cast on bearing soil
Concrete cover does not comply with codes
No reinforcing rods available for pedestal
The pedestal's provided reinforcement exceeds the maximum %
Reinforcement area provided for pedestal insufficient
The foundation's height is outside the validity field of the strut method
Load eccentricity exceeds one third of footing width
Load eccentricity exceeds one third of footing length
Sliding along XY too large
You have chosen, at the level of Arche Building Structure, an export in continuous footing despite the Finite Elements calculation. The FE forces components have been ignored.
Footing self-weight must be considered for reinforcement calculation
Warning: Loads with large eccentricities (e,x>A/3). Special precautions shall be taken (§9.5(2) from NF P94-261)
Warning: Loads with large eccentricities (e,x>A/3). Special precautions shall be taken (§6.5.4(1) from EN 1997-1)
Warning: Eccentricity e,y exceeds B/3. Special precautions shall be taken (§9.5(2) from NF P94-261)
Warning: Loads with large eccentricities (e,y>B/3). Special precautions shall be taken (§6.5.4(1) from EN 1997-1)
<<applied seismic Code>> codes are being used, as <<selected seismic Code>> codes are not available.
Reinforcement area provided for footing insufficient(bottom, X direction)
Reinforcement area provided for footing insufficient(top, X direction)
Reinforcement area provided for footing insufficient(bottom, Y direction)
Reinforcement area provided for footing insufficient(top, Y direction)
The real shear (upper) reinforcement area of the pocket is not sufficient
The real shear (lower) reinforcement area of the pocket is not sufficient
Concrete stress exceeded
Stress in lower bars exceeded
Stress in upper bars exceeded
Crack width top fiber exceeded
Crack width bottom fiber exceeded
The height of footing is too small
DCH class: cross-sectional dimensions must meet the requirements from §5.5.1.2.2 from EN1998-1
For primary seismical columns, the cross-sectional dimension must comply with §5.4.1.2.2 from EN1998-1
Normalised axial force exceeds the limit from §5.4.3.2.1 from EN1998-1. Please increase cross-sectional dimensions or concrete class.
Concrete strength class insufficient for the selected exposure class (Table E.1.1 NF from EN1992-1-1-AN France)
Loads were turned into linear loads in BST
Reinforcement not specified
Soil bearing resistance failed at ULS. Increase footing dimensions.
Load eccentricity check failed at ULS (NF P94-261)
Load eccentricity check failed at ULS
Load eccentricity check failed at SLS
Load eccentricity check failed at SLS
Bottom concrete cover of the foundation is incorrect
Top concrete cover of the foundation is incorrect
Lateral concrete cover of the foundation is incorrect
Maximum punching shear stress on concrete is exceeded (EN1992-1-1, §6.4.5)
Actual development length is less than the minimum allowable development length
Steel to concrete ratio exceeds maximum allowed ratio
Minimum diameter not respected for the main reinforcement (Clause 9.8.2.1 (1) from NF EN 1992-1-1/NA)
Minimum diameter not respected for the main reinforcement (Clause 9.8.2.1(1) from EN 1992-1-1)
The seismic bearing capacity is not ensured along X (Annex F from NF EN 1998-5/NA)
The seismic bearing capacity is not ensured along X (Annex F from EN 1998-5)
The seismic bearing capacity is not ensured along Y (Annex F from NF EN 1998-5/NA)
The seismic bearing capacity is not ensured along Y (Annex F from EN 1998-5)
Numerical inconsistencies found (equation F.1 from NF EN 1998-5/NA)
Numerical inconsistencies found (equation F.1 from EN 1998-5/NA)
The soil settlement is exceeded (SLS)
Seismic bearing capacity cannot be calculated. Condition on N normalized, F.5 from EN1998-5, is not satisfied
Seismic bearing capacity cannot be calculated. Condition on N normalized, F.8 from EN1998-5, is not satisfied.
The supported element does not respect the pedestal condition, so it will be calculated as a column
The spacing of the bottom reinforcement on X does not meet the minimum conditions
The spacing of the bottom reinforcement on Y does not meet the minimum conditions
The spacing of the top reinforcement on X does not meet the minimum conditions
The spacing of the top reinforcement on Y does not meet the minimum conditions
A convergence problem was encountered. The pressures distribution can't be calculated with precision for this foundation because in horizontal plane, it results as a pentagon having one of the edges too small.
Invalid reinforcement generated. (Review the geometry of the element)
Seismic bearing capacity (Nmax) is exceeded. The condition on V normalized (eq. F.5 (§F.2) from EN1998-5) is not satisfied.
Ground failure figure doesn't reach second level, one-layer calculation was used.
Friction angles differ too much, can't calculate multi-layer.
Bearing capacity was calculated without multi-layer because of user-settings.
The presizing algorithm could not respect all the imposed constraints.
Warning: Loads with large eccentricities (ex|ey interaction). Special precautions shall be taken (§6.5.4(1) from EN 1997-1)
Warning: Loads with large eccentricities (ex|ey interaction). Special precautions shall be taken (§9.5(2) from NF P94-261)
Transverse spacing exceeded
The linkage, if any, between the concrete fill and the footing is not calculated.
Theoretical reinforcement area is greater than maximum reinforcement area, reinforcement cage for supported element was not generated
Seismic cases are defined but seimsic bearing capacity verification is not activated (in Design Assumptions - Seismic Design)
The chosen distribution type could not be generated because the required anchorage length could not be provided. Standard distribution has been generated instead.
The footing height is not enough to consider this footing as pure concrete. Either increase footing height or change calculation type to reinforced footing
The reinforcement calculation could not be performed for at least one combination because the load eccentricity exceeds the scope of the calculation method (ex > 0.5 * A or ey > 0.5 * B).