The Reinforcement Assumptions command on the Assumptions panel, gives access to the reinforcement parameters regarding: reinforcement type (bars or fabrics, minimum and maximum bars spacing, minimum and maximum bars diameter, nodes reinforcement, particular rules for interior and exterior walls, horizontal linkage, and openings bars.
Note: The Reinforcement Assumptions dialog box content changes depending on the chosen standard.

The Reinforcement Assumptions dialog box
Eurocode General Standard
Wall Reinforcement Assumptions - Wall Web & Nodes Bars dialog box

Wall Web & Nodes Bars dialog box
1.Wall Web & Nodes Bars
Wall Web & Nodes General Settings
Main reinforcement type: define the reinforcement type to be provided for reinforced walls (Bars or Fabrics).

Main reinforcement type for wall: Bars/ Fabrics
Bars closer to wall face: choose which rebar direction is closer to the face of the wall (Horizontal Bars or Vertical Bars). This option is available only if Main reinforcement type is set to Bars (it is disabled for Fabrics).

Vertical bars closer to wall face (1) or Horizontal bars closer to wall face (2)
Transverse reinforcement type: define the transverse reinforcement type to be provided for reinforced walls (None, Stirrups, Pins).

Transverse reinforcement type: None (1), Stirrups (2), Pins (3)
Minimum transverse reinforcement quantity: define the minimum quantity per square meter of transverse reinforcement. When generating transversal bars both this minimum imposed value and the recommendations from 9.6.4. (1) and 9.5.3 from EN1992-1-1 are considered. The option is greyed when Transverse reinforcement type is set to None.

Smaller value for Minimum transverse reinforcement quantity (4/m2)

Bigger value for Minimum transverse reinforcement quantity
Transverse bars only for bars closer to wall face: generate transversal bars only for the bars closer to the face of the wall (vertical or horizontal bars, not for both).

Transverse bars only for bars closer to wall face option unchecked (1), checked (2) - example with horizontal bars closer to wall face
Adjust bending diameter for transverse bars: the bending diameter for pins and stirrups will be the maximum value between the defined Transversal Bending Diameter and the diameter of the longitudinal bar linked by that pin or stirrup.

Adjust bending diameter for transverse bars unchecked (1), checked (2)
Nodes reinforcement type: select the method for linking the longitudinal bars in nodes either using additional links or extending the existing horizontal bars in walls.

Nodes reinforcement type: Rectangular links (1), Extend horizontal bars (2)

Extend horizontal bars in nodes: checked (1), unchecked (2)
Extend stiffeners internal links inside node: check this option to extend pins or stirrups from stiffeners inside the node. Otherwise, additional pins or stirrups will be generated for the longitudinal bars inside the node.

Extend stiffeners internal links inside node: unchecked (1), checked (2)
2.Slab Starter Bars

Provide top starter bars: checked (1), unchecked (2)
Rebar type: define the starter bars diameter.
Spacing: define the starter bars spacing.
Length: define the starter bars vertical length.
3.U-shaped Edge Bars

U-shaped Edge Bars dialog box
U-shaped Edge Bars Settings
Identical settings for interior and exterior walls: check this option if you want to apply the same settings for interior and exterior walls. If this option is not checked, you can define the following settings differently for interior and exterior walls.
Provide left/right edge U-shaped bars: provide U-shaped bars along the left/right edge of the wall; not available for shear walls with edge stiffeners. If vertical linkage bars are being calculated for a wall, U-shaped bars will not be generated.

U-shaped bars and vertical constructive bars
Rebar type: define U-shaped edge bars diameter.
Spacing: define U-shaped edge bars spacing.
Length: define the U-shaped edge bars horizontal length.
Number of vertical constructive bars: define the vertical constructive bars number.

Number of vertical constructive bars
Rebar type of vertical constructive bars: define the vertical constructive bars diameter.
4.Last Level Linkage Bars

Last Level Linkage Bars dialog box
Vertical Linkage Bars Settings
Identical settings for interior and exterior walls: check this option if you want to apply the same settings for interior and exterior walls. If this option is not checked, you can define the following settings differently for interior and exterior walls.
Generate vertical linkage: provide vertical linkage bars at wall edges

Provided vertical linkage bars at wall edges
Current levels: provide vertical linkage bars not only along the last level height but also along current levels height; applies only if Strips method is used for efforts calculation.
Minimum diameter: define the minimum vertical linkage bars diameter. If the theoretical reinforcement area is not covered using the minimum imposed diameter, the diameter will be automatically increased.
Horizontal Bars under Terrace Settings
The options in this section are greyed if the option Generate horizontal linkage is not checked (Horizontal Linkage Bars dialog).
Identical settings for interior and exterior walls: check this option if you want to apply the same settings for interior and exterior walls. If this option is not checked, you can define the following settings differently for interior and exterior walls.
Position: define the position for horizontal bars under terrace (Under slab or With horizontal linkage).

Horizontal Bars under Terrace position: Under slab (1), With horizontal linkage (2)
5.Fabrics

Fabrics dialog box
Identical settings for interior and exterior walls: check this option if you want to apply the same settings for interior and exterior walls. If this option is not checked, you can define the following settings differently for interior and exterior walls.
Impose fabric type: the generated fabric type will be the fabric having the maximum vertical reinforcement area between the automatically generated and the imposed one.
Fabric type: define the fabric type from the available options.
Extension length: define the fabric extension length above the wall.

Fabrics extension length
Cover: define the concrete cover of the wire fabric.

Fabric cover
6.Horizontal Linkage Bars

Horizontal Linkage Bars dialog box
Horizontal Linkage General Settings
Generate horizontal linkage

Provided Horizontal linkage bars
Minimum longitudinal diameter: define the inferior limit for horizontal linkage bars.

Effect of Minimum longitudinal diameter option

Traversal bars shape set to Pins
Transversal spacing define the transversal reinforcement spacing.
7.Opening Bars

Openings Bars dialog box
Lintel Transversal Bars
Minimum lintel height: define the minimum height of the lintel.
Rebar type: define the lintel links diameter.
Offset: define the offset of the first lintel link from the opening edge.

Lintel Transversal Bars Offset
Spacing: define the lintel links spacing.
Enclosed links shape

Enclosed links shape set to Pins
Openings Constructive Bars
Minimum diameter: define the minimum opening vertical bars diameter.
8.Constraints

Constraints dialog box
Number of Bars Constraints
Impose the number of certain vertical and horizontal bars depending on wall thickness.
Vertical: refers to vertical left/right edge linkage and constructive vertical bars for openings.
Horizontal: refers to longitudinal bars from opening’s lintel, constructive horizontal bars for openings, horizontal longitudinal linkage and horizontal bars under the terrace.
Related topics