The Diagram command displays specific diagrams for each wall in the group under the applied external loads.
The available diagrams are:
- Applied normal stress [MPa]
- Average strip normal stress [MPa]
- Applied normal force [kN/m]
- Average strip normal force [kN/m]
- Base normal stress [MPa]
Note: If only Resultant forces are defined in Loads dialog, the only diagram available is Base normal stress. The rest of the diagram require external loads to be applied (in Loads-Vertical tab from Loads dialog).

The Diagram window
Diagrams are available for all generated combinations, at top, middle and bottom of the wall or at an imposed height, “h”.

Normal stress diagrams at middle and top of wall
For additional details, at any abscissa of the wall, you can activate the ruler and the plot details window.

Ruler and the plot details window
User has also the possibility to save current view as a picture and to print the current view.

Save and Print tools for diagrams
Several options to personalize the graphic of the diagrams are also available: diagrams discretization with arrows, bars or no discretization and the possibility to fill or not the diagrams area.

Normal stress diagram discretization with arrows
Normal stress diagram not filled
Related topics