Sliding & Strut Bars

 

 

The Sliding & Strut Bars item opens a dialog box that provides information about sliding and Strut-and-Tie bars.

 

 

 

The Sliding & Strut Bars dialog box

The Sliding & Strut Bars dialog box

 

 

 

 

Sliding Bars Settings

Verify bottom reinforcement to be anchored, provided at supports: the tensile force to be anchored may be determined including the contribution of the axial force if any and, for the intermediate supports, the contribution of bending moment, in accordance with 9.2.1.4 from EN 1992-1-1

Imposed diameter: if checked, the sliding reinforcement diameter will be imposed by the user. If unchecked, the diameter will be equal with the diameter of the bars in tension

Maximum distance for extension: define the maximum distance from which the reinforcement bars are not extended

Extend support bars in spans: extend the reinforcement from support into the beam

Strut-and-Tie Bars Settings

Shape: define the bar shape for the strut-and-tie reinforcement provided in accordance with 6.5.4 from EN 1992-1-1:

 

- Straight

Straight

 

- U-shaped

 

U-shaped

 

Increase maximum stress by 10%: increase the maximum stress with 10% according to 6.5.4(5) from EN 1992-1-1

 

 

 

 

 

 

Related topics