The EN 1991-1-3 NA Snow loads family is created when the Eurocodes 1 (EC1) - Germany climatic standard is selected for the current project.

EN 1991-1-3 NA Snow loads family - Properties
Name: the default name of the family.
No.: displays the ID number of the family.
Category: allows the selection of the snow region type. When selecting user-defined, is possible to define custom values for the combination coefficients.
Define properties that are taken into account when generating concomitance combinations. See Configuring load cases combinations.
Group loads: when enabled, each load case inherits "combinations" properties from the corresponding load case family and will be grouped as a generic load case in the concomitance matrix.
Effect: sets the load case as "Leading", "Accompanying" or both.
Coefficient γ EQU: partial factor for seismic action considered in the EQU ultimate limit state
Coefficient γ STR/GEO: partial factor for seismic action considered in the STR/GEO ultimate limit state
Ψ0 coefficient: factor that defines the combination value of a variable action
Ψ1 coefficient: factor that defines the frequent value of a variable action
Ψ2 coefficient: factor that defines the quasi-permanent value of a variable action
Exceptional snow accumulation: enables/disables the snow accumulation option.
Exceptional snow fall: enables/disables the exceptional snow fall.
Typical value: defines the snow region. Each region is defined by certain snow loads values. To set custom values for the snow loads, select Other.
The
button displays the snow regions map and allows the
selection of the corresponding region.

Regions for EN 1991-1-3 NA snow loads family
Snow load: automatically calculated according to the selected region. A custom value (in kN/m2) can also be set.
Exceptional snow load: automatically calculated according to the selected region. A custom value (in kN/m2) can also be set.
Exposure factor: allows the selection of the location type: swept by the winds, normal or protected.
Thermal factor: the thermal coefficient (Ct) varies in special cases (when the roofs have high thermal transmittance ( > 1 W/ m2 K ), in particular for some glass covered roofs, because of melting caused by heat loss). In all other cases, Ct = 1.00.
Altitude: allows the definition of the location altitude.
View / change the representative color for the family.
Tip
Click a section of the properties window. Notice the bottom area of the window; it displays a short description of the active cell's content.
After creating a snow load case family: in the Project Browser, expand the Loading group and select Snow EN 1991-1-3 NA.