Generalized Buckling Analysis

 

The generalized buckling analysis is used for the study of amplified loads that lead to an elastic instability corresponding to the Eulerian buckling. Buckling analysis is possible for structures composed of planar and linear elements (except for cable elements).

Several buckling analysis cases can be defined. Each buckling case refers to a static load case or to a combination of static load cases.

The general buckling analysis parameters are defined in the properties window of the Generalized buckling load case.

 

 

How to create a generalized buckling analysis family

Use these methods to access the command:

 

 

The Select the analyses dialog box appears. Allows selecting loads and creating multiple cases at once by clicking All, None or selecting them manually.

 

Select the analyses

Select the analyses

 

 

A generalized buckling analysis family is created in the Project Browser, under Settings, along with a buckling case.

 

Generalized buckling analysis family

Generalized buckling analysis family

 

 

How to select the analysis

  1. In the generalized buckling load case properties window, Reference field, click to open the Select the analyses dialog box.

Select analyses dialog box

Select the analysis to assign in the buckling analysis

 

 

  1. Select the analysis (i.e., load case or combination) to assign in the buckling analysis.
  2. Click OK to apply and close.

 

How to delete generalized buckling analyses

 

The selected analysis is deleted. When deleting the generalized buckling family, all the corresponding load cases are deleted.

 

 

 

Related Topics